English | Korean

CG320-Fever Screening Camera

 

cg300cg600

CG320 Remark
Resolution(Pixels) 384×288
Spectral response  8-14µm Un-cooled LWIR micro-bolometer
Thermal Detector Pixel Pitch 17µm
Thermal Sensitivity          (NETD) <50mK @f1.0, 30Hz, 300K
Operating temperature     (ambient temperature) (Installing thermal cameras inside housing with built-in fan and heater to keep inside temperature in a certain range, for example, 15 to 25℃, is recommended for use in out of operating temperature range for accuracy in measurement)
Range of temperature measurement 0 ℃~60 ℃  Thermal camera set at normal temperature detection mode has better accuracy in measurement
Accuracy +/-0.5℃ at around 25℃
Range of temperature mesurement distance 0.5m ~ 30m
System Video Output BNC connector(composite), HDMI
Temperature data output via Ethernet port(Giga E)
Data refresh rate 30Hz
Video frame Rate BNC connector(composite): NTSC 30Hz, PAL 25Hz HDMI: 480p, 576p, 720p, 1080i,
HDMI: Selectable 1080p selectable
Ethernet Giga Ethernet(10/100/1000Mbps)
Lens 8.1mm athermalized lens
Power 4W 220VAC to 12VDC (including adoptor)